A fixture that flickers or reacts to the wrong fader? Nine times out of ten, it's the addressing. Here is the complete method, with the maths.

The principle: a universe of 512 channels

A DMX line is a universe: 512 channels numbered 1 to 512. Each channel carries a value from 0 to 255. All 512 values are sent continuously, on a single cable, to every fixture on the line.

Each fixture only reads its own block of consecutive channels. Its DMX address is the first channel of that block. A PAR in 8-channel mode set to address 1 reads channels 1 to 8: the next fixture therefore starts at 9. All of DMX addressing comes down to this rule.

Rough figures: one universe is enough for almost every band, DJ or village hall rig. 20 PARs in 8 channels and 4 moving heads in 16 channels make 224 channels, less than half a universe.

The channel mode, to choose first

Most fixtures offer several modes: 3, 7, 8 or 10 channels for an LED PAR, 9, 14 or 16 channels for a moving head. The short mode gives fewer controls, the long mode gives everything: dimmer, each colour, strobe, macros.

The mode is set in the fixture's menu, often shown as « 7CH », « 8CH » or « d-8 ». The manual gives the DMX chart for each mode, channel by channel. Keep it at hand.

The rule: the same mode for all identical fixtures, and the same mode in the software as on the fixture. A different mode shifts every control: the channel the software thinks is red actually drives the strobe.

Address your fixtures in 6 steps

  1. List your fixtures in the order they will be cabled, with the model and the chosen mode for each.
  2. Write down the number of channels of each mode, from the manual.
  3. Calculate: next address = previous address + number of channels of the previous fixture. The first one is at 1.
  4. Check that the last channel used does not go past 512. Beyond that, move part of the rig to a second universe.
  5. Set the address and the mode on each fixture, in its menu or with its DIP switches.
  6. Write the addressing plan on a sheet, stick it in the flight case, and put a label with the address on each fixture.

Worked example: a dance band

The rig: 8 LED PARs in 8-channel mode, 2 spot moving heads in 14-channel mode, a DMX smoke machine on 1 channel.

  • PAR 1 to 8: addresses 1, 9, 17, 25, 33, 41, 49 and 57. PAR 8 uses channels 57 to 64.
  • Moving head 1: address 65 (channels 65 to 78).
  • Moving head 2: address 79 (channels 79 to 92).
  • Smoke machine: address 93.

Total: 93 channels out of 512. There is room to double the rig.

Now you switch the PARs to 10-channel mode to get white and amber. Everything shifts: PARs at 1, 11, 21, 31, 41, 51, 61 and 71, moving heads at 81 and 95, smoke at 109. That is why you choose the modes before setting a single fixture.

A rental tech's tip: leave gaps and start from round numbers. PARs from 1, moving heads at 101 and 121, effects at 201. You can do the maths in your head, and add a PAR without redoing everything.

For a wedding DJ with 4 PARs in 7 channels and 2 derbys in 6 channels: PARs at 1, 8, 15 and 22, derbys at 29 and 35. Ten minutes of setup, once and for all.

Setting the address on the fixture

On a fixture with a display, you type the address in the menu (often « A001 », « Addr » or « d001 »). On older PARs and some effects, the address is set with a row of small switches, the DIP switches.

Each switch is worth a power of 2: 1, 2, 4, 8, 16, 32, 64, 128, 256. You switch ON the ones that add up to the address. For address 65: 64 + 1, so switches 1 and 7. For 79: 64 + 8 + 4 + 2 + 1, so switches 1, 2, 3, 4 and 7. Some models count differently, or reserve the last switch for another setting: check the manual.

Cabling: daisy-chain, terminator, cable

A DMX line is daisy-chained: interface to the DMX IN of the first fixture, its DMX OUT to the DMX IN of the next, and so on. No Y-splits: to go in two directions you need a DMX splitter. Count 32 devices per line at most; beyond that, a splitter starts a fresh line.

On the DMX OUT of the last fixture, plug in a terminator: an XLR plug with a 120 Ω resistor between pins 2 and 3. Without a terminator, the signal bounces back at the end of the line. On a long line, fixtures flicker or drop out at random.

The cable: proper DMX cable, with 3- or 5-pin XLR. It has the same connector as a mic cable, but not the same impedance (110 to 120 Ω). A cheap mic cable will do for 5 metres, not for 30.

Common mistakes

  • Overlap: two fixtures share channels. They react together, in strange ways (the red of one triggers the strobe of the other). Redo the maths.
  • Wrong mode: the fixture is in 6 channels, the software expects 8. Colours are wrong and everything after it is shifted.
  • The same address on two identical fixtures: on purpose, they do exactly the same thing (handy for two front PARs); otherwise a source of confusion, because you can no longer control them separately.
  • The forgotten terminator, or a mic cable in the middle of the line.
  • A fixture left in auto or sound mode: it ignores DMX. Set it to DMX mode in its menu.

With LWA Light

In LWA Light Controleur, you describe your rig in the Wizard: model, mode, quantity. DMX addresses are calculated automatically and follow on from left to right. The mode you choose just has to match the one on the fixture.

The Universe tab shows each fixture, its channels and its start address. An address already in use is refused (« Overlapping addresses »). If you change a fixture to a longer mode, the following ones shift just as much as needed. « Reorder and readdress » recalculates everything: you drag the fixtures into the order you want, choose the universe, the start address and free channels between two fixtures, and the software warns you if it goes past 512.

For the get-in, the addressing tool shows which DIP switches to set ON for a given address. The addressing plan prints to PDF, and it is also on the free remote: you set the fixtures from the stage, phone in hand. See also The tools and the compatible hardware.

LWA Light Controleur Wizard, 3D Placement step: stage and truss settings on the left, PARs and moving heads placed on the top-view plan on the right
The Wizard: in step 1 you add the rig and the addresses follow on; in step 2 you place the fixtures on stage.
LWA Light Controleur Today's rig window: moving heads and PARs present or absent, with the fixture of the same model replacing each absent one
Today's rig: a fixture missing tonight is replaced by a present one of the same model, with the same channels. Hence the point of using the same mode for all identical fixtures.

Try LWA Light for free

30 days, every tool unlocked, on Windows, Mac or Linux.

Free trialWatch the video tutorials

Frequently asked questions

How many fixtures can you put on one DMX universe?

As many as their channel total allows: 512 channels in all. With PARs in 8 channels, that makes 64 PARs. On the cable side, count 32 devices per line at most, then a splitter.

Do you really need a DMX terminator?

Yes, on the DMX OUT of the last fixture: a 120 Ω resistor between pins 2 and 3. On a short line you can sometimes do without, but it is the first thing to check when a fixture flickers or drops out.

Can a mic cable replace a DMX cable?

As a stopgap, over a few metres. DMX cable has an impedance of 110 to 120 Ω, suited to the digital signal. On a long line or with many devices, a mic cable causes flickering.

Can two fixtures have the same address?

Yes, if they are the same model and in the same mode: they will do exactly the same thing. If you want to control them separately, give them different addresses.

What do you do when you go past 512 channels?

Move part of the fixtures to a second universe, with a second output: a two-output DMX-USB interface or an Art-Net node. Addresses start again from 1 on each universe.